RESTORATION | DEHUMIDIFIERS
DRI-EAZ DEHUMIDIFIERS
®
®
DRI-EAZ REVOLUTION TM DRI-EAZ EVOLUTION DRI-EAZ LGR 7000XLI DEHUMIDIFIER
LGR DEHUMIDIFIER LGR DEHUMIDIFIER
F413 F292 F412
ITEM NO. REVOLUTION F413 EVOLUTION F292 7000LXI F412
Pints per day at AHAM 80 pints / 38 L 70 pints / 33 L 130 pints / 61.5 L
Weight 65 lbs / 29.5 kg 92 lbs / 42 kg 107 lbs / 49 kg
Amp Draw 6.0 A 5.0 A 8.3 A
Operating Temps 33°-100° F 33°-100° F 33°-100° F
Humidistat Yes No Yes
Blower CFM 121-180 CFM 160 CFM 325 CFM
Volts 115V 115V 115V
Filter F372 F372 F368
HOW MANY DEHUMIDIFIERS DO I NEED?
DETERMINING HOW MANY DEHUMIDIFIERS TO PLACE DEHUMIDIFIER FACTORS TABLE
1 Determine the cubic footage of the affected area L x W x H CLASS 1 CLASS 2 CLASS 3 CLASS 4 UNITS
2 Note the dehumidifier rating of pint removal at AHAM for LGR's & Conventional Cu ft.
Conventionals. For desiccants, use the process out CFM from the refrigerant 100 40 30 N/A per pint
manufacturer's specifications.
Cu ft.
LGR 100 50 40 50
3 Determine the classification of water loss. per pint
Desiccant 1 2 3 2 ACH
4 Check the dehumidifier factors table.
Cu ft. ÷ factor = AHAM pints required (refrigerants) CLASS 1 : wet plywood, concrete, lumber and other dense materials and/or wet carpet pad.
Factor x Cu ft. ÷ 60 = CFM required (dessicants) CLASS 2 : typically whole rooms of wet carpet & pad with water wicking less than 24" up wall
CLASS 3 : whole rooms of wet carpet & pad with water wicking more than 24" where water
* Formulas are intended for initial set up only. has come from above
CLASS 4 : specialty drying with materials containing deep pockets of saturation with slow
evaporation potential
This formula was designed to create a balanced drying system that
achieves a goal of 40% relative humidity or less within 24 hours. ACH = Air changes per hour.